Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
J Geriatr Cardiol ; 19(5): 354-366, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35722037

RESUMO

OBJECTIVES: Elderly patients show a higher incidence of ischemic and bleeding events after percutaneous transluminal coronary intervention (PCI). We sought to investigate outcomes in elderly patients treated with antithrombotic strategy guided by bleeding and ischemic risks after revascularization with last generation everolimus-eluting stent (EES). METHODS: Prospective multicenter registry including patients over 75 years revascularized with EES and antithrombotic therapy guided by clinical presentation, PCI complexity and PRECISE DAPT score. Co-primary safety endpoints were: (1) composite of cardiac death, myocardial infarction and stent thrombosis and; (2) bleeding (BARC 2-5). Primary efficacy endpoint was target lesion revascularization. A matched group of patients revascularized with current drug-eluting stents and no such tailored antithrombotic therapy was used as control. RESULTS: Finally, 1064 patients were included in SIERRA-75 cohort, 80.8 ± 4.2 years, 36.6% women, 71% acute coronary syndromes (ACS) and 53.6% complex PCI. Co-primary safety endpoint of major adverse cardiovascular events was met in 6.2%, co-primary safety endpoint of bleeding in 7.8% and primary efficacy endpoint of TKLR in 1.5%. The multivariable adjusted model showed no significant association of the prescribed short/long dual antiplatelet therapy (DAPT) durations with any endpoint suggesting a well tailored therapy. No stent thrombosis reported in the subgroup with 1-3 months DAPT duration. As compared to control group, bleeding BARC 2-5 was significantly lower in SIERRA-75 group (7.4% vs. 10.2%, P = 0.04) as well as the net safety-efficacy endpoint (14.3% vs. 18.5%, P = 0.02). CONCLUSIONS: In elderly population, the application of this risks-adjusted antithrombotic protocol after revascularization with last generation EES seems to be associated with an improved prognosis in terms of ischemic and bleeding outcomes.

3.
Rev. colomb. cardiol ; 29(2): 177-184, ene.-abr. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1376876

RESUMO

Resumen Introducción: La angioplastia con balón es una técnica que ofrece buenos resultados, especialmente en los casos de recoartación tras cirugía correctora. Objetivo: Analizar los resultados de un centro hospitalario a partir de la introducción de la técnica. Método: Se analizaron 73 pacientes con una edad media de 3.3 años; el 74% eran menores de 1 año y el 72.6% estaban por debajo de 10 kg de peso. Todos los pacientes incluidos fueron casos de recoartación tras cirugía correctora. Resultados: Se observó un resultado efectivo en el 93.1% de los casos, con gradiente residual < 20 mmHg. Durante el seguimiento, el 20.5% precisaron reintervención, la cual fue más frecuente en caso de angioplastia sobre el arco, lesiones asociadas y menores de 1 año. Solo se objetivó una complicación grave relacionada con el procedimiento, que correspondió a una rotura aórtica que no pudo ser solventada con implante de stent cubierto. Conclusiones: La angioplastia percutánea de recoartación de aorta es una técnica segura y efectiva, en especial en los casos de recoartación tras cirugía correctora de lesiones circunscritas al istmo.


Abstract Introduction: Balloon angioplasty is a technique with good outcomes, specially in cases aortic recoartation after correcting surgery. Objective: To analyze our centre results since the introduction of the technique. Method: We analyzed 73 patients with medium age of 3,3 years; 74% were under 1 years old and 72,6% under 10 kg weight. All patients included were cases of recoartation after surgery. Results: Effective results was achieved in 93,1%, obtaining residual gradient less than 20 mmHg. During the following up 20,5% of patients required reintervention, being more frequent in case of aortic arch hypoplasia, associated lesions or patients under 1 year. Only a severe complication was referred, a case of aortic rupture that couldn’t be solved with a covered stent. Conclusions: Percutaneous angioplasty of aortic recoartation is a safe and effective technique, specially in discrete istmic lesions after correcting surgery.

4.
Cardiovasc Drugs Ther ; 34(3): 335-344, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32212061

RESUMO

OBJECTIVES: The objective of this post hoc analysis was to analyze real-world dual antiplatelet therapy (DAPT) regimens following polymer-free sirolimus-eluting stent (PF-SES) implantations in an unselected patient population. METHODS: Patient-level data from two all-comers observational studies (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled and analyzed in terms of their primary endpoint. During the data verification process, we observed substantial deviations from DAPT guideline recommendations. To illuminate this gap between clinical practice and guideline recommendations, we conducted a post hoc analysis of DAPT regimens and clinical event rates for which we defined the net adverse event rate (NACE) consisting of target lesion revascularization (TLR, primary endpoint of all-comers observational studies) all-cause death, myocardial infarction (MI), stent thrombosis (ST), and bleeding events. A logistic regression was utilized to determine predictors why ticagrelor was used in stable coronary artery disease (CAD) patients instead of the guideline-recommended clopidogrel. RESULTS: For stable CAD, the composite endpoint of clinical, bleeding, and stent thrombosis, i.e., NACE, between the clopidogrel and ticagrelor treatment groups was not different (5.4% vs. 5.1%, p = 0.745). Likewise, in the acute coronary syndrome (ACS) cohort, the NACE rates were not different between both DAPT strategies (9.2% vs. 9.3%, p = 0.927). There were also no differences in the accumulated rates for TLR, myocardial infarction ([MI], mortality, bleeding events, and stent thrombosis in elective and ACS patients. The main predictors for ticagrelor use in stable CAD patients were age < 65 years, smaller vessels, treatment of ostial and calcified lesions, and in-stent restenosis. CONCLUSION: Within the framework of a post hoc analysis based on a real-world, large cohort study, there were no differences in the combined endpoint of major adverse cardiac events (MACE), bleeding and thrombotic events for clopidogrel and ticagrelor in stable CAD or ACS patients. Despite the recommendation for clopidogrel by the European Society of Cardiology (ESC), real-world ticagrelor use was observed in subgroups of stable CAD patients that ought to be explored in future trials.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Terapia Antiplaquetária Dupla , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/administração & dosagem , Sirolimo/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Terapia Antiplaquetária Dupla/efeitos adversos , Terapia Antiplaquetária Dupla/mortalidade , Feminino , Fidelidade a Diretrizes , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
5.
Medicine (Baltimore) ; 99(8): e19119, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32080086

RESUMO

Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.


Assuntos
Antibacterianos/uso terapêutico , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/uso terapêutico , Implantes Absorvíveis/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/cirurgia , Idoso , Implante de Prótese Vascular/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus/epidemiologia , Stents Farmacológicos/tendências , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/complicações , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Polímeros , Padrões de Prática Médica/normas , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...